VWR SympHony SP70P Multi-parameter Portable pH Meter
$ 47.52
- Description
- Size Guide
Description
VWR® Benchtop MetersSupplier:
VWR, part of Avantor
Specially designed for use in the laboratory, these rugged and durable benchtop meters are versatile enough to fit your unique testing needs.
Simple to operate and maintain
Consistently accurate and reliable measurements
Configurable to each user's unique needs
VWR three-year limited warranty
Available with ISO/IEC 17025 NIST traceable calibration certificate
These meters are simple to operate and offer an intuitive user interface allowing for easy set up and use from day one.
Calibrated pH meters and kits include a Troemner ISO/IEC Accredited Calibration Certificate traceable to NIST. The ISO/IEC 17025 Accredited Calibration Certificate includes electrical simulation of multiple data points within the functional ranges with the associated uncertainties. Troemner is accredited by NVLAP under Laboratory Code 105013-0 to perform ISO/IEC 17025 calibrations.
Step-by-step on screen prompts enable both new and seasoned users to operate the meter easily and effectively, resulting in consistently accurate measurements.
Certifications:
VWR® sympHony™ benchtop meters meet IP54 specifications for protection from water and are CE and cETLus marked.
Ordering information:
Stand is not included with the meter kits. Each benchtop meter can be configured to fit your needs with the variety of optional electrodes, stands with stirrers, and accessories available.
Less Product Information
SPECIFICATIONS
pH Range
-2 to 19
-2 to 19
pH Resolution
0.1/0.01/0.001
0.1/0.01/0.001
pH Accuracy
≤ 0.002 pH (± 1 digit)
≤ 0.002 pH (± 1 digit)
ISE Range
10-5 to 10-1 mol/L
10-5 to 10-1 mol/L
ISE Units
mol/L, M, g/L, mg/L, μg/L, mmol/L, mM, µmol/L, or %
mol/L, M, g/L, mg/L, μg/L, mmol/L, mM, µmol/L, or %
Conductivity Range
0.001 µS/cm to 1000 mS/cm
0.001 µS/cm to 1000 mS/cm
Conductivity Resolution
Variable, autorange
Variable, autorange
Conductivity Accuracy
≤ 0.5% m.v. ± 1 digit
≤ 0.5% m.v. ± 1 digit
Resistivity accuracy
≤ 0.5% m.v. ± 1 digit
≤ 0.5% m.v. ± 1 digit
Salinity Range
Automatic, with manual data entry (0-45 ppt)
Automatic, with manual data entry (0-45 ppt)
DO Resolution (mg/L)
0.01 mg/L in the range of 0.00 to 19.99 mg/L
0.1 mg/L in the range of 20.0 to 60.0 mg/L
0.1 % in the range of 0.0 to 19.9%
1% in the range of 20 to 600%
0.01 mg/L in the range of 0.00 to 19.99 mg/L
0.1 mg/L in the range of 20.0 to 60.0 mg/L
0.1 % in the range of 0.0 to 19.9%
1% in the range of 20 to 600%
DO Accuracy
≤ 0.5% m.v. ± 1 digit
≤ 0.5% m.v. ± 1 digit
DO Salinity Factor (ppt)
Automatic, with manual data entry (0-45 ppt)
DO Range
0.00 to 60.0 mg/L
0.00 to 60.0 mg/L
Resistivity Range
0.0001 to 100 MΩ
0.0001 to 100 MΩ
Resistivity Resolution
Variable, autorange
Variable, autorange